Hi, I also had a small problem installing the VM Essentials Manager 9.1. The installer broke network bonding. By default, the HVM installation is missing the bond parameter "mii-monitor-interval: 100". When I added this setting to the bonding, the VM Essentials installation was successful. Also, during the VM Manager installation, I used an existing management bond VLAN and did not create a new one during the process.